A screw that spins without tightening has stripped its threads, usually in the softer of the two parts—an aluminum bracket, a sheet-metal panel, or a machine casting. The durable repair is to restore a real thread rather than pack the hole: drill or ream to the insert's specified size, tap if the insert calls for it, install a threaded insert, and drive the original-size screw into that. For light loads in thin or non-critical metal, a chemical metal filler or a larger screw can work instead, but it holds far less force. The choice depends on the metal's thickness, whether you can reach both sides, and how much load the joint carries.
Here's what matters before you pick up a drill: a stripped hole is a size problem, not a grip problem. Anything you add to the hole has to be anchored to sound metal, so the first task is identifying the metal, its thickness, and whether there is room behind it. Aluminum and castings take inserts well but gall easily; thin sheet metal needs blind or rivet-style inserts because there may be nothing behind the hole to tap into.
Why a stripped hole fails and what a repair must achieve
A machine screw holds because its threads engage matching internal threads over a certain length. Thread engagement is the real currency here: the screw needs enough full turns in sound material to carry the load without the threads shearing or pulling out. In soft metals like aluminum, the internal threads wear or shear first; in thin sheet metal, the threads were marginal to begin with and a little over-torque tears them out.
That gives three repair routes, and they're not equivalent:
Restore a thread of the same size in stronger material. A threaded insert does this: it replaces the damaged threads with a harder, larger-diameter threaded body that itself is anchored in the surrounding metal. Bond a new thread into the hole. A chemical metal filler (an epoxy-based metal-filled compound) can be drilled and tapped after curing, but its strength is limited by the bond to the hole wall. Use a bigger fastener. A self-tapping or thread-forming screw of the next size up cuts its own threads in the existing hole—fast and effective, but it changes the fastener size and may not suit a visible or precision part.
Each has a legitimate use, and picking wrong is the most common failure. A filler in a high-vibration engine bracket will crack loose; a same-size insert in 0.5 mm sheet metal has nothing to grip.
One useful failure story makes the point: a stripped M6 hole in an aluminum motorcycle case cover patched with epoxy filler and re-tapped often survives a few heat cycles, then the filler debonds and the screw backs out. The same hole with an M6 threaded insert in a properly drilled and tapped boss usually outlasts the surrounding threads. The difference is anchorage, not the screw.
Prerequisites: identify the metal, the thread, and the access
Before anything, confirm four things. Getting these wrong wastes the repair.
-
Thread size and pitch. Use a thread pitch gauge or match a known screw. Metric coarse M6 is 1.0 mm pitch; M8 is 1.25 mm; M10 is 1.5 mm. Unified inch sizes (1/4-20, 5/16-18, 10-24) differ in pitch, and mixing them strips a freshly repaired hole immediately. If you don't know the size, measure the screw's outside diameter with calipers and check the pitch against a gauge or a matching nut.
-
Metal type and thickness. Aluminum, steel, stainless, zinc die-cast, and magnesium behave differently. Thickness sets the maximum insert length and rules out methods: blind inserts need roughly 1.5× the screw diameter in material depth for a secure hold, and thin sheet needs a rivet-nut or a folded/self-clinching style rather than a solid-walled insert.
-
Access to the back. If the hole is blind (a boss or casting), you need a blind insert. If you can reach both sides, you have more options, including through-bolting with a nut and washer—often the strongest and simplest fix of all, and worth considering before any threaded repair.
-
Load and consequence. A cosmetic cover screw tolerates a filler repair. A structural bracket, a load-bearing machine mount, or a fastener near a safety-critical part (brake caliper, suspension, lifting point) does not. For those, use a proper insert or through-bolt, or hand it to a machinist or the equipment maker's service agent.
Have on hand: the correct drill bit for the insert's specified size, the matching tap if the insert requires one, the insert and its installation tool, cutting fluid for aluminum or stainless, a center punch, and a way to keep the drill perpendicular (a drill block or a drill-press if the part is removable).
Method 1: Threaded inserts (the durable same-size repair)
Threaded inserts come in several families, and the method differs by type. Choose by material and access.
Solid-wall (key-locking) inserts are the strongest for castings and thicker metal. They install with a specific tap and are locked with keys driven down. Wire-thread inserts (helical coils) are thin-walled, restore the original thread size, and suit aluminum and magnesium where you want minimal material removal. Blind inserts (sometimes called blind rivet nuts when they're the rivet style) install from one side and are the answer for sheet metal and closed structures. Self-tapping inserts cut their own threads in a drilled hole, needing no tap, which is convenient where a tap can't reach.
The general sequence for a tapped solid-wall or wire insert:
1: Center and drill. Punch the center of the damaged hole, then drill to the insert's specified drill size—not the screw's size. For a wire insert restoring M6, the drill is typically around 6.3 mm for the tap size the insert requires; for a solid-wall insert the drill and tap are larger, per the insert's data sheet. Keep the drill perpendicular; a tilted hole tilts the screw. 2: Deburr and clean. Remove chips and any raised metal around the rim. Chips left in a blind hole prevent the insert seating and can jam the tap. 3: Tap (if required). Use the tap specified for the insert, with cutting fluid for aluminum or stainless, going a half-turn forward and a quarter-turn back to break chips. For blind holes, mark the tap or count turns so you don't bottom out and snap it. 4: Install the insert. Thread it in with the installation tool until it sits flush or just below the surface—never proud, which prevents the part seating. For key-locking inserts, drive the locking keys after installation to expand and anchor the insert. 5: Check and drive the screw. Run the original screw in by hand first. It should turn freely and tighten without spinning. If it spins, the insert isn't locked or the hole was oversized; stop and re-evaluate rather than adding torque.
Success check: the screw reaches snug torque with a normal turn or two past finger-tight, and the insert doesn't rotate when you loosen the screw. If the insert turns, it isn't anchored—remove it and step up to a larger insert or a different method.
Limits and failure cases. A wire insert in a hole whose wall is too thin will pull out under load, taking a cone of metal with it—worse than the original damage. A solid-wall insert in a shallow boss bottoms out and cracks the boss. And an insert installed into a hole that was already enlarged by a previous failed repair has no purchase; at that point, the honest fix is to weld or braze the hole and re-drill, or replace the part.
Method 2: Chemical metal filler (light loads only)
Metal-filled epoxy can restore a stripped hole for low-load, non-critical fasteners. The repair relies on the epoxy bonding to clean, roughened metal and then holding threads cut into it.
1: Clean and roughen. Degrease thoroughly—solvent, then dry—and abrade the hole walls with a small wire brush or rolled abrasive. Epoxy won't bond to oil or oxide. 2: Plug the far side if needed. For a through-hole, tape or a backing washer keeps the filler in place while it cures. 3: Mix and fill. Follow the product's mix ratio exactly; most metal-filled epoxies are 1:1, but check the label. Overfill slightly and press it into the hole to avoid voids. 4: Cure fully before drilling. This is the step people rush. Most metal epoxies need 24 hours at room temperature for full strength; a "quick" handling time of minutes isn't full cure. 5: Drill and tap the filler to the original size. Use the standard tap drill for the screw size and cut threads carefully, backing out to clear chips. Then drive the screw gently—snug, not cranked. 6: Check the result. The screw should hold light hand torque. Test with the actual service load before trusting it; a filler repair is not a structural fix.
Where it fails. Heat cycling, vibration, and solvent exposure all degrade the bond. Filler repairs also can't be re-torqued repeatedly, and they're a poor match for a fastener that's removed often. For a bolt that sees vibration, an insert or through-bolt will outlast it by a wide margin.
Method 3: Upsizing or through-bolting (simple and strong)
Upsize by re-drilling and tapping to the next size (M6 to M8, 1/4-20 to 5/16-18) and fitting the matching screw. This is fast and needs no insert, but it changes the fastener size, may need the clearance hole in the mating part opened up, and can't be repeated indefinitely—each step weakens the remaining material. It's a good choice when the hole is in a thick boss and you just need a working fastener.
Through-bolt is often the strongest simple fix when both sides are accessible: drill the stripped hole to clearance for a bolt, and use a nut and washer on the far side. That eliminates the thread-in-metal problem entirely. The catch is clearance behind the part and whether a nut and washer will fit without fouling moving parts.
Both approaches need the same discipline as inserts: correct drill size, perpendicular hole, and a check that the new fastener doesn't bottom out or protrude into something it shouldn't.
Matching the repair to metal and thickness
Three practical rules save a lot of rework.
Thin sheet (under about 1 mm): use a rivet-nut or blind insert. A tapped insert has too little material to grip, and filler is nearly useless. Through-bolting with a washer on each side is the alternative.
Aluminum castings and thick bosses: wire-thread inserts or solid-wall key-locking inserts. Aluminum galls, so use cutting fluid and don't force a dull tap.
Stainless steel: taps and inserts work, but stainless work-hardens; use sharp tooling, slow speed, and plenty of lubricant. Never hammer a stainless insert into place.
Zinc die-cast: so soft that even an insert can pull out under load. Consider through-bolting or redesigning the joint rather than trusting the original thread depth.
Magnesium: flammable chips are a real hazard when machining; use appropriate precautions and never machine dry—this is a job for a qualified shop if the part matters.
A quick calculation helps set expectations: the load a thread carries scales with engagement length and the material's shear strength. Doubling engagement in the same material roughly doubles capacity, but an insert in soft aluminum doesn't automatically double it—the insert's own anchorage is the weak link. That's why a long insert in soft metal can still pull out before the screw breaks.
Troubleshooting and stop conditions
Symptom: the screw spins after an insert install. The insert isn't anchored (keys not driven, wrong interference fit) or the hole was oversized. Don't add torque; remove and step up.
Symptom: the tap snaps. Usually a bottomed-out blind hole or chips jammed in the flutes. Use a spiral-flute tap for blind holes and clear chips often.
Symptom: the filler repair works, then fails after a month. Vibration or heat cycling debonded it. Switch to an insert or through-bolt.
Symptom: the hole keeps growing with each repair. Stop upsizing. Weld/braze and re-drill, or replace the part—repeated enlargement removes the material an insert needs.
Stop and get qualified help when the fastener is structural or safety-related (vehicle suspension or braking, lifting equipment, pressure systems, aircraft), when the part is expensive or hard to replace, when the metal is magnesium, or when the hole is in a casting with internal passages that a drill could breach. For anything under warranty, check with the manufacturer before modifying it.
For most workshop and household repairs, the sequence is unglamorous: measure the thread, pick the insert family that fits the material and access, drill and tap to the insert's spec, install, and verify with the original screw. The filler and upsizing routes are fine for light loads—just be honest with yourself about which kind of joint you're fixing.