Cedar shakes are made by felling mature western red cedar, bucking logs into shake blocks, splitting those blocks along the grain with a froe and mallet, then squaring and resawing the split pieces to a taper of roughly 3/8 to 3/4 inch at the butt. Machines speed the work, but the split still follows natural grain, which is why a shake is riven rather than sawn. That single fact explains much of what follows about durability, texture, and failure.

Splitting along the grain

A tree becomes a shake because wood is anisotropic: its properties differ by direction. Western red cedar (Thuja plicata) forms distinct growth rings of earlywood and latewood, and the boundary between them is a weak plane. A froe driven parallel to the rays peels the block apart along those planes rather than cutting across them, so the split follows the same fibers from butt to tip.

This is why riving, not sawing, defines a true shake. A sawn shingle severs fibers at its faces, exposing cut end-grain that absorbs water. A riven shake's face is essentially a natural fiber surface, and the split tends to follow the grain's own taper. The visible result is the characteristic ridged face; the functional result is a board with fewer severed fibers to wick moisture inward.

The tree itself must cooperate. Old-growth western red cedar, typically 4 to 8 feet in diameter on the stump, yields long straight grain and few knots. Knots are where a shake will break during splitting, so clear wood is the target. Second-growth timber with more knots and faster growth produces shorter, more brittle material, which shifts the supply toward sawn products or engineered alternatives.

From stump to shake block

Harvesting a mature cedar is the upstream half of the process. Loggers fell the tree, buck the trunk into lengths (often 16 to 24 inches for the shake block, though longer blocks yield longer shakes), and transport them to a mill or shake shed. The critical selection step is grain inspection: a block splitter reads the end grain and bark to find a block that will rive cleanly rather than crumble.

At the shed, the block is set on a chopping block or in a cradle and split with a froe, a long blade with a handle perpendicular to it. The splitter drives the froe through the block with a mallet, steering it to follow the grain. Each pass yields a shake blank; the blank is then squared at the sides and often re-split or sawn to a taper. Machine splitting uses a hydraulic wedge that mimics the same principle, which is why mill output still depends on the raw material's grain quality.

The counterintuitive part: a perfectly straight, knot-free block is not automatically good shake stock. Grain runout, compression wood, and spiral grain can all make a block split diagonally or shatter. Experienced splitters reject blocks that a machine would happily force through, which is why hand-split and machine-split material can differ in yield even from the same log.

Quantified context: dimensions, grades, and coverage

Standard cedar shake dimensions are set by consensus trade practice, not a single statute, so values vary by region and buyer. A common hand-split shake runs 18 to 24 inches long, 4 to 14 inches wide, and 3/8 to 3/4 inch thick at the butt, tapering to about 1/8 inch at the tip. A heavy "resawn" shake is sawn on one or both faces after splitting to hit a flatter profile.

Coverage depends on exposure, the vertical overlap between courses. At a typical 10-inch exposure, a square (100 square feet of roof area) needs roughly 100 to 110 shakes per course, and a full roof consumes around 1,000 to 1,200 shakes per square when accounting for overlap and waste. Wider shakes cover more area per piece, so coverage is usually specified by the square rather than by count.

Grading separates appearance from performance. The Cedar Shake and Shingle Bureau's grading system, used widely in North America, distinguishes shakes by face and durability characteristics; a No. 1 grade is largely clear, while lower grades permit more defects. Buyers should ask which grading system the supplier uses, because "cedar shake" alone says nothing about grade.

Product How it is made Typical use Durability profile Main tradeoff
Hand-split shake Froe and mallet, natural grain split Roofs, feature cladding Good natural water shedding Labor-intensive, irregular faces
Resawn shake Split then sawn faces Roofs needing flatter profile Similar to split, flatter face Lost some natural surface
Sawn shingle Saw-cut from blocks Roofs, siding More end-grain exposed Lower initial water resistance
Pressure-treated shake Chemical preservative applied High-moisture exposure Extended service under some conditions Treatment compatibility matters
Composite/synthetic shake Molded from polymers or fiber cement Fire-prone or low-maintenance sites Fire and rot resistant Aesthetic and cost differences

Comparison is only like-for-like when exposure, substrate, and climate are held constant. A treated shake and a synthetic shake are not equivalent products; one relies on wood chemistry, the other on material substitution.

Timeline of a cedar shake roof

The manufacture is fast; the service life is long and conditional. A typical sequence looks like this, but no row is a guaranteed schedule.

Stage Typical time Notes
Felling and bucking Hours per tree Depends on access and equipment
Block splitting and shaping Minutes per block Yields vary with grain quality
Air drying Weeks to months Moisture content affects installation
Kiln drying (if used) Days Reduces shrinkage after installation
Installation Days per roof Weather dependent
Initial weathering First 1 to 2 years Color shift and surface checking begin
Service life 20 to 40+ years Depends on ventilation, climate, maintenance

The 20-to-40-year range is a broad estimate, not a specification. A roof over a poorly ventilated attic in a wet climate can fail far sooner, while a shaded, well-vented installation in a dry climate can exceed it. The condition that changes the outcome most is ventilation: trapped moisture under the shakes drives rot.

Edge cases and the moisture problem

Cedar's natural durability comes from extractives, particularly thujaplicins, that resist fungi and insects. That resistance is real but not absolute. It declines when the wood stays wet, because repeated wetting leaches extractives and because fungal decay requires only sustained moisture and moderate temperature.

The edge cases that matter:

North-facing slopes and shaded roofs dry slowly and are more prone to moss and rot. Roofs over unvented or poorly vented attic spaces trap moisture and accelerate decay. Shakes installed green can shrink and open gaps, which increases water entry. Fastener choice matters: galvanized or stainless nails resist corrosion; plain steel can stain and fail. Fire exposure is a genuine limitation in wildland-urban interface zones; untreated cedar is combustible. Coastal salt spray and high humidity shorten service life unless the wood is treated or well ventilated.

The professional caveat: a cedar roof's performance is largely a ventilation and detailing problem, not a wood-species problem. Most premature failures trace to installation defects, not to the shake itself.

Misconceptions about cedar shakes

Cedar shakes are not simply "cedar shingles" under another name. A shingle is sawn; a shake is split. The distinction affects water behavior, texture, and often cost.

Cedar is not uniformly rot-proof. Western red cedar is more decay-resistant than many softwoods, but no untreated wood resists rot indefinitely when wet. The extractive protection is a rate reducer, not a guarantee.

Bigger shakes are not always better. A very thick, wide shake can cup and split as it dries unevenly, and heavy shakes need stronger fastening and substrate. The right dimension depends on exposure and span, not on maximizing size.

Synthetic shakes are not identical substitutes. They solve fire and maintenance problems that wood cannot, but they change the roof's weight, sound, and repairability profile. Buyers comparing them to cedar should compare the same outcome (water shedding, fire performance, service life) under the same conditions, not just price per square.

Practical actions for buyers and installers

Before purchasing, verify the grading system and moisture content. A moisture meter reading on a sample batch gives a concrete check; kiln-dried material behaves differently on the roof than green material. Ask for the supplier's grade documentation and confirm the grading authority.

During installation, confirm the ventilation path above the roof deck and the underlayment specification. The observable check is airflow at the eave and ridge; if the attic cannot breathe, the shakes will stay wet. The main failure condition is a sealed deck with no ventilation gap.

Verify grade and moisture content before delivery. Confirm substrate and underlayment meet the manufacturer's or code requirements. Check fastener type and penetration depth against the local code. Inspect ventilation at eaves, ridge, and any obstructions. Plan for fire-rated assemblies if the site is in a high fire-risk zone. Schedule periodic inspection and remove debris from valleys and gutters.

Prerequisites: local building code, climate zone, and the manufacturer's installation instructions. The observable result is a dry, ventilated assembly; the failure condition is trapped moisture with no drying path.

Limitations and what this article cannot settle

This is a general explanation of a stable manufacturing process, not construction advice. Specific fire ratings, code requirements, and installation standards vary by jurisdiction and change over time, so the reader must confirm local requirements with the authority having jurisdiction. Service-life figures are ranges from experience, not guarantees. For any roof project, consult a licensed contractor and the local building department before proceeding.